Lucene search

K

SIMATIC MV400 Family Security Vulnerabilities

cve
cve

CVE-2020-25241

A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). The underlying TCP stack of the affected products does not correctly validate the sequence number for incoming TCP RST packages. An attacker could exploit this to terminate arbitrary TCP...

7.5CVSS

7.4AI Score

0.001EPSS

2021-03-15 05:15 PM
21
cve
cve

CVE-2019-13946

Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable...

7.5CVSS

7.3AI Score

0.001EPSS

2020-02-11 04:15 PM
83
cve
cve

CVE-2019-10926

A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). Communication with the device is not encrypted. Data transmitted between the device and the user can be obtained by an attacker in a privileged network position. The security vulnerability can be exploited by an...

5.3CVSS

6.6AI Score

0.003EPSS

2019-06-12 02:29 PM
59
cve
cve

CVE-2019-10925

A vulnerability has been identified in SIMATIC MV400 family (All Versions < V7.0.6). An authenticated attacker could escalate privileges by sending specially crafted requests to the integrated webserver. The security vulnerability can be exploited by an attacker with network access to the device...

7.1CVSS

6.6AI Score

0.001EPSS

2019-06-12 02:29 PM
62
cve
cve

CVE-2017-2681

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI....

6.5CVSS

6AI Score

0.001EPSS

2017-05-11 10:29 AM
56
2
cve
cve

CVE-2017-2680

Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not...

6.5CVSS

6.2AI Score

0.003EPSS

2017-05-11 01:29 AM